TCP/UDP

Connections and Ports

Any TCP/IP enabled client device can connect and communicate with the CM1-T. The table below lists the ports and protocols they are associated with

Protocol

Port #

# TCP

# UDP

Description

CML

10001

1

1

Protocol used by the standard motor. Program the motor to run from IO, etc.

Direct Control Port

10002

1

1

Directly control the motor in a number of modes such as position, speed and torque

  • The CM1-T Library can be used with the Direct Control port 

Modbus TCP

502

1

0

Modbus access to all motor registers including CML and Direct Control.

  • The CM1-T Library can be used with the Modbus TCP port

Motor Information Port

30718

0

1

  1. Query the motors configuration (Network configuration, serial number, etc)

  2. Query/Stream the motors information (status, position, speed, etc)

EtherNet/IP

44818
2222

2
0

1
1

EtherNet/IP CIP
EtherNet/IP IO

  • The CM1-T Library can be used with the EtherNet/IP port

This section focus on the Direct Control Port and the Motor Information port. For information on the other protocols go to their specific section.

Direct Control Port  

Port 10002 can be used to read and write the Direct Control registers. TCP/IP or UDP can be used.

Write Data Packet

This is the data received by the motor on a write from the TCP/UDP Client.

  • TCP/IP or UDP

  • Port 10002

  • Length = 28 bytes

Data

Byte

Register

Size/Type

Description

0-3

TargetPosition

DINT

Final target position

4-7

TargetSpeed

DINT

Maximum targetspeed

8-9

TargetTorque

INT

Maximum torque

10-11

TargetAccelertion

INT

Acceleration (used when accelerating to target speed)

12-13

TargetDeceleration

INT

Deceleration  (used when stopping)

14-15

Controlword

INT

Control the motor operation

16

ModeOfOperation

SINT

Set the required mode of operation

17

DigitalOUT

SINT

Set the 2 digital outputs. Requires K34=44.

18-19

WriteAddress1

INT

Address of the motor register to write to

20-23

WriteValue1

DINT

Value to be written to the motor register

24-25

ReadAddress1

INT

Address of the motor register to read

26-27

PAD

INT

16-bit padding not used

Read Data Packet

This is the data transmitted by the motor to the TCP/UDP Client when a write packet is received

  • TCP/IP or UDP

  • Port 10002

  • Length = 36 bytes

Data

Byte

Register

Size/Type

Description

0-3

us50Counter

DINT

CPU clock time in 50us counts

4-7

ActualPosition

DINT

The actual position of the motor in encoder counts

8-11

MotionTarget

DINT

The actual instantaneous position the motor is currently moving to.

12-15

ActualSpeed

DINT

Actual speed of the motor in encoder counts/s

16-17

MotorStatus

INT

The motors status (error, homing, in position, etc)

18-19

PercentActualCurrent

INT

Percentage (0.1%) of rated current. 1000 = rated, 1100 = peak.

20-21

PercentOverloadTorque

INT

Percentage (0.1%) of overload torque.

22-23

AnalogIN

INT

10 bit analog input value (0-1023)

24-25

DCVoltage

INT

24V DC bus voltage in 0.1V

26

DigitalIN

SINT

Digital IN status. B0-B3 = IN1-IN4

27

Temperature

SINT

Drive temperature in ºC

28

ModeOfOperationDisplay

SINT

Indicates the mode of operation currently set

29

ErrorCode

SINT

Error code on communication error

30-31

ReadAddress1

INT

Address of the motor register for ReadValue1

32-35

ReadValue1

DINT

The value in the motor register displayed in ReadAddress1

Motor Information Port  

The motor information port is used to query the motor configuration data as well as all status data. The status data can also be set to stream out at defined time intervals.

  • Port 30718

  • UDP only

The motor receives a 4 byte data packet which indicates the type of request. The response includes a 4 byte header. The request and expected response header are defined as such:

Command

B3 (Command ID)

B2

B1

B0

1

Configuration Request

0xF6

0x00

0x00

some data

Configuration Response

0xF7

0x00

0x00

echo some data

2

Information Request

0xF4

Time ms high byte

Time ms low by

some data

Information Response

0xF5

Counter high byte

Counter low byte

echo some data

Configuration Data

The configuration data responds with info regarding the motor's network configuration, firmware versions and serial number

To request the configuration data send the following data packet

Byte

Value

Description

0

0x00-0xFF

Any value. This will be echoed back on the response

1

0x00

Ignored

2

0x00

Ignored

3

0xF6

Command ID for configuration request

The response packet is returned as follows

Bytes

Description

0

Echo of some data

1-2

0x0000

3

0xF7 (Command ID)

4-11

N/A

12-15

Current IP Address

16-19

Subnet Mask

20-23

Gateway IP

24-29

MAC Address

30

DHCP Enabled

31

N/A

32-35

CM1-T Interface Firmware Version

36-39

CM1 Drive Firmware Version

40-99

Part Number (ascii)

100-103

Reserved

104-105

Production Date

106-107

Product ID

108-109

Serial Number

110-118

CM1-T Interface Hardware Version

119

Reserved

Information Data

The information request returns a complete set of the motor's state data including, position, speed, drive status, IO, etc

Send Data

To request the information data send the following data packet:

length = 4 bytes

Byte

Value

Description

0

0x00-0xFF

Any value. This will be echoed back on the response

1

0x00

Interval Time in ms low byte

2

0x00

Interval Time in ms high byte

3

0xF4

Command ID for information request

Interval Time

The Interval Time is a 16 bit value that sets the response interval in ms. It has the following characteristics

  • Value range: [0-65536]

  • If value = 0 then the query sends a single response

  • If value > 0 then a response is sent at the interval time

Receive Data

The following data is received on a request or on an interval response

length = 33 bytes

Byte

Name

Description

0

Data echo

Echo the data sent in B0 of the request

1-2

Counter Value

Each response increments the counter value. A query resets the counter.

3

0xF5 - Command ID

Response command ID is 0xF5

4-7

CPUTime

CPU clock time in 50us counts

8-11

ActualPosition

The actual position of the motor in encoder counts

12-15

ActualTargetPosition

The actual instantaneous position the motor is currently moving to.

16-17

MotorStatus

The motors status (error, homing, in position, etc)

18-19

ActualRatedCurrent

Percentage (0.1%) of rated current. 1000 = rated, 1100 = peak.

20-21

ActualOverloadTorque

Percentage (0.1%) of overload torque.

22-23

AnalogIN

10 bit analog input value (0-1023)

24

DigitalIN

Digital IN status. B0-B3 = IN1-IN4

25

Temperature

Drive temperature in ºC

26-27

DCVoltage

24V DC bus voltage in 0.1V

28

DigitalOUT

Digital OUT status. B0-B1 = OUT1-OUT2

29

Reserved

-

30

ModeOfOperationDisplay

Indicates the mode of operation currently set

31

ActualSpeed

Actual speed of the motor in encoder counts/s

Example Packets

The following example uses Packet Sender to execute some direct moves, query configuration and query information.

Please be aware of any firewall restrictions especially when using UDP.

Name

Send Data Bytes

Direct - Clear Error

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 20 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Disable

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 10 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Halt & Clear Start Bit & Enable

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 02 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Run to 0

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 01 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Run to 1000

E8 03 00 00 10 00 00 00 4C 04 64 00 64 00 01 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Set current pos to 0

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 40 00 03 00 00 00 00 00 00 00 00 00 00 00

Direct - Start Home Search

00 00 00 00 10 00 00 00 4C 04 64 00 64 00 80 00 03 00 00 00 00 00 00 00 00 00 00 00

Query Config

00 00 00 f6

Query Info

00 00 00 f4

Query Info 1s

00 e8 03 f4

  • Direct - Run uses a speed = 10, acceleration = 100, deceleration = 1000 and Torque = 1100.

The image below shows Packet Sender with the response to Query Info

The Packet Sender database for the above example can downlaoded here - CM1-T Example.ini