Introduction

The CM1-T is an Ethernet based Cool Muscle. It offers all the functionality of the standard Cool Muscle but enables connections over TCP/IP, UDP and Modbus-TCP. This variant of the Cool Muscle cannot be daisy chained.

In additional to the standard CML programming other modes of operation have been implemented which gives the application direct access the motion routines. See Modes Of Operation for additional details. This chapter focuses on the standard operation of the motor using CML.

Connection

Any TCP/IP enabled client device can connect and communicate with the CM1-T. Additional connection information can be found in Network Configuration but in general:

  1. Connect on port 10001 for CML communication.
  2. Send and receive ASCII strings within the data packet.
  3. Modbus-TCP can be connected on port 502. This gives modbus access to all the motor's registers.

Usage

CML Programming

Refer to the RT3 Programming Manual for details on using CML. You will find information on the following in this manual.

  • K parameters (setup parameters)
  • H parameters (postion controller gain parameters)
  • Motor registers (position, speed, acceleration, torque, etc)
  • Variable registers
  • Program banks
  • Logic banks
  • Inputs and Outputs


As stated in the introduction the CM1-T is a standalone motor and cannot be used in a daisy-chain configuration. As such there are features in CML related to multiple motor networks which will not function if programmed.