Version # | Update Information | Firmware | XML |
---|
V1.3.3 | Revision #: 0x20020103 (No XML update. Revision number is not changed) - Feature updates
- Target velocity in CSV mode is now in count/s. Previously it was counts/ms
- Velocity Actual Value is now in counts/s. Previously was in counts/ms
| MYO28ECV133.hex | Myostat_CM1-E (V1.3.0).xml |
V1.3.2 | Revision #: 0x20020103 (No XML update. Revision number is not changed) - Feature updates
- PDO communication rate now includes multiple periods.
- Specifically 200us, 250us, 500us and 1ms.
- No setting is required on the slave/drive which autodetects the rate.
- Bug fixes
- OUT LED indicator fixed.
| MYO28ECV132.hex | Myostat_CM1-E (V1.3.0).xml |
V1.3.0 | Revision #: 0x20020103 - Feature Updates
- SM and PDI watchdog implemented. The motor will disable if a watchdog timeout is encountered
- Mode of Operation and Mode of Operation Display have been added to the Profile Mode RxPDO and TxPDO respectively.
- Statusword BIT12 is implemented for CSV and CSP mode. BIT12 indicates if the drive is following the commanded position.
- EEPROM data is included in the update and will load automatically.
- Revision # is updated with each release. The matching XML is required. This allows for multiple version on the same network.
- Bug fixes
- Halt bit on Homing Mode would not halt the motor when switching modes at the same time.
- Speed for HM and PP mode is now correctly returned. It was 1/4 or the actual value.
- General improvements on task handling and timing.
| MYO28ECV130.hex | Myostat_CM1-E (V1.3.0).xml |
V1.2.0 | - Feature Updates
- F/W update through FoE in Bootstrap.
- Object 0xFF01 - Status LED override
- Bug Fixes
- SDO objects now available in all ESM states. In previous versions the entire
dictionary was not available until the slave had transitioned into OP at least one.
| | |
V1.1.3 | - Added support for Explicit Device ID
- Improved SDO data transfer
| |
|
V1.1.2 | - Improved USB communication for
- Changing H gain parameters
- Running the motor in CML mode
- Updating firmware
| |
|
For information on how to update the CM1-E firmware please contact Myostat support