Comment: added speed control
Metadata (Metadata Plugin)
0version
hiddentrue
1.0.0
Scroll Ignore

Button export page pdf

Version:

Metadata from
1version

 

The speed parameters in the motor are measured in pulses per second. The values you program in the motor are a multiple of the speed unit that is set in parameter K37. By Default, this speed unit is set to 100 pulses per second. This means that if you set the motors speed value to 50, the rotational speed of the motor will be 100pps x 50 = 5000 pulses per second.

In order to calculate the speed of the motor in revolutions per minute, you would use the following formula:

Imageplus
imagealigncenter
imageidSpeed

For example, using the above speed value of 50, the default speed unit of 100, and 1000 pulse per revolution resolution:
Imageplus
imagealigncenter
imageidspeed2

 

When moving the motor, the sign of the speed is ignored, unless the position is set to 1,000,000,000. If this is the case, the motor will move indefinitely with no target position. The direction is then determined by whether the speed is a negative or positive value. If the speed is 0, the motor will stop.