ParameterRead/WriteDescription
Firmware VersionReadCurrent CM1-T firmware version
MAC AddressReadMAC address of the CM1-T
Current IP AddressReadThe IP address that the CM1-T is currently using
DHCP EnabledRead/WriteIndicates whether the CM1-T should use DHCP or a static IP
IP AddressRead/WriteIP address if DHCP is not enabled
Default GatewayRead/WriteDefault gateway if DHCP is not enabled
Subnet MaskRead/WriteSubnet mask if DHCP is not enabled
CML Socket TypeRead/WriteSocket type TCP or UDP
CML Socket Port #Read/WritePort # for CML connection. Typically 10001
Modbus Socket TypeRead/WriteSocket type TCP or UDP
Modbus Socket Port #Read/WritePort # for Modbus-TCP connection. Typically 502

test

...

CM1-T Configuration Tool

draw.io Diagram
borderfalse
diagramNameConfig
simpleViewertrue
width1000
linksauto
tbstyletop
diagramDisplayName
lboxtrue
diagramWidth1391
revision34

Setting IP Properties

The IP on the Cool Muscle can be set as static or configured to use DHCP to assign the IP.

...

The main status LED on the motor will flash yellow green while it is waiting to be assigned an IP address. It will be solid green if an IP has been assigned.

If no DHCP server is found the CM1-T IP search will timeout. In this case the CM1-T will self assign an address in the 169.254.xxx.xxx rangeTHE DHCP search will not time out.

Static IP

The CM1-T can be assigned an IP address, default gateway and subnet mask. In addition the final octet in the IP can be set by the rotary switches on the side of the motor.

...