Register | Description |
---|---|
CPUTime | CPU clock time in 50us counts |
ActualPosition | The actual position of the motor in encoder counts |
ActualTargetPosition | The actual instantaneous position the motor is currently moving to. |
MotorStatus | The motors status (error, homing, in position, etc) |
ActualRatedCurrent | Percentage (0.1%) of rated current. 1000 = rated, 1100 = peak. |
ActualOverloadTorque | Percentage (0.1%) of overload torque. |
AnalogIN | 10 bit analog input value (0-1023) |
DigitalINDigitalIO | Digital INIO status.
|
Temperature | Drive temperature in ºC |
DCVoltage | 24V DC bus voltage in 0.1V |
DigitalOUT | Digital OUT status. B0-B1 = OUT1-OUT2 |
ModeOfOperationDisplay | Indicates the mode of operation currently set |
ActualSpeed | Actual speed of the motor in encoder counts/s |
...