Parameter | Read/Write | Description |
---|---|---|
Firmware Version | Read | Current CM1-T firmware version |
MAC Address | Read | MAC address of the CM1-T |
Current IP Address | Read | The IP address that the CM1-T is currently using |
DHCP Enabled | Read/Write | Indicates whether the CM1-T should use DHCP or a static IP |
IP Address | Read/Write | IP address if DHCP is not enabled |
Default Gateway | Read/Write | Default gateway if DHCP is not enabled |
Subnet Mask | Read/Write | Subnet mask if DHCP is not enabled |
CML Socket Type | Read/Write | Socket type TCP or UDP |
CML Socket Port # | Read/Write | Port # for CML connection. Typically 10001 |
Modbus Socket Type | Read/Write | Socket type TCP or UDP |
Modbus Socket Port # | Read/Write | Port # for Modbus-TCP connection. Typically 502 |
test
...
CM1-T Configuration Tool
draw.io Diagram | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Setting IP Properties
The IP on the Cool Muscle can be set as static or configured to use DHCP to assign the IP.
...
The main status LED on the motor will flash yellow green while it is waiting to be assigned an IP address. It will be solid green if an IP has been assigned.
If no DHCP server is found the CM1-T IP search will timeout. In this case the CM1-T will self assign an address in the 169.254.xxx.xxx rangeTHE DHCP search will not time out.
Static IP
The CM1-T can be assigned an IP address, default gateway and subnet mask. In addition the final octet in the IP can be set by the rotary switches on the side of the motor.
...