The following diagram shows an overview of all connectors and LEDs.
Figure: Overview of Connections and status LEDs
The EtherCAT IN and OUT ports use standard Ethernet RJ45 CAT5e connectors.
|
The power connector supplies 24V to the EtherCAT slave and the motor separately. These two can be tied together so both are off the same power supply.
The power connector is an M9 circular connector from Binder. The relevant parts numbers are
Connector | Part Number | Supplier |
---|---|---|
Motor connector | 09 0081 20 04 | Binder |
Female cable side mating connector | 99 0080 102 04 | Binder |
4m power cable | CM1M9-4F-4000 | Myostat |
|
Connector | Part Number | Supplier |
---|---|---|
Motor connector | 09 0481 22 08 | Binder |
Female cable side mating connector | 99 0480 102 08 | Binder |
4m I/O cable | CM1M9-8F-4000 | Myostat |
|
The USB connector is a standard micro USB and is used to update the EtherCAT firmware. When it is plugged into a computer it will create a virtual serial port.
An EtherCAT slave device is required to have LEDs indicating different states.
There is a Link/Activity LED for both the IN and OUT EtherCAT ports. The table below describes the indicator conditions and their associated states
Link | Activity | Condition | Link/Activity Code |
---|---|---|---|
Yes | No | Port Open | On |
Yes | Yes | Port Open | Flickering |
No | N/A | Port Closed | Off |
The Run indicator shows the state of the EtherCAT State Machine. The indicator states are described in the table below.
Indicator State | Slave State | Description |
---|---|---|
Off | Initialisation | The device is in state "Init" |
Blinking | Pre-Operational | The device is in state "Pre-Operational" |
Single Flash | Safe-Operational | The device is in state "Safe-Operational" |
On | Operational | The device is in state "Operational" |
Flickering | Init or Bootstrap | The device is booting and has not yet entered the "Init" state or, |
The Error indicator shall show device and EtherCAT errors. Errors are as defined in the table below.
Error State | Error Name | Description | Example |
---|---|---|---|
On | Application controller | A critial communication or application error has occured |
|
Double flash | Process Data Watchdog timeout/ EtherCAT watchdog timeout | An application watchdog timeout has occured | Sync Manager watchdog timeout |
Single flash | Local Error | Slave device application has changed the EtherCAT state autonomously, due to local error. | Device has changed from Op to safe-op due to EtherCAT error |
Blinking | Invalid Configuration | General Configuration error | |
Flickering | Booting Error | Init state reached but boot error detected | Application boot error |
Off | No Error | Device is in working condition |
The system status LED provides feedback to the user on overall system status. The following states exist
LED Colour | Description |
---|---|
Red | Motor Error Solid:
Blinking
Flashing:
|
Green | Solid - CiA402 Mode |
Blue | Solid - CML Mode |