Comment: Added PDO timing

...

For backwards compatibility with certain master controllers the Configured Station Alia Alias Register 0x0012 may be used. The following conditions exist:

Explicit Device ID
Value
Configured Station Alias
Value
Usage
00No identification used or expected
>00Explicit Device ID is used
0>0Configured Station Alias is used
>0>0Internal error generated


PDO Timing
Anchor
PDO Timing
PDO Timing

The CM1-E slave will accept a number of PDO rates. The rate is auto-detected and no additional setup is required on the slave.

Accepted rates are

  1. 1000μs (1ms)
  2. 500μs
  3. 250μs
  4. 200μs

The detected rate can be read in object 0xFE00:1. 

PDO Mappings 
Anchor
PDO Mappings
PDO Mappings

...